€18,350.01
€15,040.99 excl. VAT
Available, delivery time: 1-2 weeks
VERIFIED STENT WEIGHING · BUILT-IN NEUTRON CSL
RADWAG XA 5Y.M.A.S-M — precise weighing, connected laboratory workflows
Bring your stent weighing and digital records together. This verified configuration combines dedicated sample handling with integrated Neutron CSL, so your team can move weighing results directly into the software it uses every day.
Less manual work. More useful weighing data.
- For laboratory operators: a clear route from sample identification to measurement and recording.
- For quality teams: organise results around sample or batch identifiers in your receiving application.
- For IT and integrators: connect the balance to your infrastructure through documented network protocols.
- For purchasing teams: the communication module is already built in, avoiding a separate external CSL gateway.
Designed for delicate stents
Dedicated stent pans and holders make sample placement easier. An ionizer, automatic chamber doors and automatic levelling help operators manage practical challenges at the weighing bench. Pair the instrument with suitable environmental control and your laboratory method to obtain dependable results.
Neutron CSL is included — connect each result to the next step
The built-in CloudScaleLink Neutron CSL bridges the balance and local or cloud software. Configure result capture to reduce repeated typing and transcription errors, and shorten the route from measurement to reporting.
- Laboratory systems: integrate with LIMS and QMS workflows.
- Business and production systems: deliver results to ERP, MES, databases and custom applications.
- Scale Monitor: connect weighing data to your selected cloud workflow.
- Local deployment: send data to your own application or private broker when an on-premise architecture is preferred.
Application connectors, cloud services and integration work are specified separately to match your project.
Built for your IT architecture
Neutron CSL supports HTTP/HTTPS and REST integration, MQTT/MQTTS, WebSocket/WSS and TCP/IP. Select the transport, destination and authentication for your environment; use TLS-capable transports where encrypted communication is required. Network options depend on the installed CSL configuration.
Define when a measurement is accepted, how stability and units are handled, and which identifiers accompany the result. Sample IDs, operator details and timestamps can be combined in the receiving application with the data exposed by the balance. Agree field mapping, duplicate handling and recovery behaviour before rollout.
Verified weighing with clear metrological information
This listing is for the verified XA 5Y.M.A.S-M configuration. The displayed increment d = 1 µg and verification interval e = 1 mg describe different aspects of the instrument. Readability alone does not specify measurement uncertainty. State the installation country and intended use when ordering so the verification documentation and supplied configuration can be matched to your application.
| Weighing model | XA 6.5Y.M.A.S, supplied in the verified configuration |
|---|---|
| Maximum capacity | 6.1 g |
| Readability (d) | 1 µg (0.001 mg) |
| Verification interval (e) | 1 mg |
| Accuracy class | OIML class I |
| Adjustment / levelling | Automatic internal adjustment / ReflexLEVEL |
| Display | 10-inch colour touchscreen |
| Pan / chamber | Ø30 mm plus dedicated stent pans / 199 × 170 × 217 mm |
| Instrument interfaces | USB-A, USB-C, RS-232, HDMI, Ethernet, Wi-Fi and Hotspot |
| Protection | IP43 |
A complete weighing workstation
The stent weighing equipment includes two dedicated pans, two holders and two glass covers, alongside the microbalance with ionizer, terminal, power supply and dust cover. Our supplied configuration adds built-in Neutron CSL. We can help specify printers, barcode identification and workstation accessories around your process.
From instrument to controlled workflow
Build the data flow around your procedures: identify the sample, capture the accepted measurement, associate the result with the correct record, and make it available for review. For regulated electronic records, define validation, access controls, retention and audit requirements across the complete solution.
Frequently asked questions
What is this balance designed for?
It is designed for stent weighing, with dedicated sample-handling accessories. This listing covers the verified configuration supplied with built-in Neutron CSL.
What does built-in Neutron CSL add?
It connects weighing results to your digital workflow without a separate external CSL gateway. Configured data capture helps reduce manual typing and transcription errors.
Can we connect it to LIMS, QMS or ERP?
Yes. Neutron CSL supports HTTP/HTTPS, REST integration, MQTT/MQTTS, WebSocket/WSS and TCP/IP. The connector, field mapping and implementation are specified for your target application.
Do we need a cloud service?
The balance can work independently, and CSL can be configured to transfer data to local applications or a private broker. Cloud services are optional and are agreed separately.
Is 1 µg readability the same as verified accuracy?
No. Readability is the displayed increment; verification uses a different scale interval. Accuracy and uncertainty also depend on the instrument and actual measurement conditions.
How do we identify samples and batches?
Your integration can associate each accepted result with sample or batch identifiers in the receiving application. Define identifier entry, available instrument fields and result-capture rules during implementation.
Does verification cover the complete digital workflow?
Instrument verification and digital workflow validation address different requirements. Define access controls, electronic records, retention and validation for the connected solution.
What information should we provide for a quotation?
Send your sample dimensions, expected masses, method requirements, installation country, verification needs and target software. Include desired accessories and network requirements.
Specify your connected stent-weighing solution
Tell us your sample dimensions, weighing method, verification destination and target software. We will help match the balance, Neutron CSL configuration and integration to your laboratory.
Discuss your application with PRECIZLogin